PRE-FOUNDATION
Geotechnical Investigation (Soil test)
Conducting Soil Investigation to determine the SPT Value for the proposed construction.
Derivation of a Soil Test Report with suitable recommendations for the foundation based on the soil investigation.
SUPER STRUCTURE
RCC framed structure with RCC columns, beams and slabs.
Walls using Wire Cut Bricks.
FOUNDATION
Earthquake resistant RCC framed structure with suitable foundations based on the geotechnical Investigation report.
Anti-Termite treatment in compliance with IS 6313-2001.
Basement height (From existing road level to car park flooring level) shall be 2'6" feet.
Basement filling with filling soil, topped and consolidated with 6 inches of M.Sand and 6 inches of PCC with a mix ratio of 1:4:8.
FLOORING & WALL TILES
Living, Dining and Bedrooms shall have First quality vitrified tiles from SOMANY/RAK/KAJARIA of 4 feet x 2 feet tiles with 4 inches height skirting.
Bathrooms shall have First quality wall tiles of 2 feet x 1 foot glazed/matt from SOMANY/RAK/KAJARIA and flooring shall have matching first quality anti-skid tiles.
DOORS
Main Entrance Door: Teak wood frame & shutters with natural walnut veneered solid panel shutter.
Internal Door: Steam beach wood frame with laminate finish.
Toilet Door: Tubular core shutter.
WINDOWS
UPVC windows with Mosquito Mesh.
MS grill in all windows.
Locks from YALE/DORSET.
KITCHEN
Black Granite counter top with QUARTZ sink.
CP fittings from JAQUAR/KOHLER.
Provision for exhaust fan, refrigerator, water purifier.
Adequate power points for all Kitchen appliances.
Ceramic/Printed tiles on the wall 2 feet above the counter top.
PAINTING
Internal walls and ceiling shall be finished with 2 coats BIRLA wall care putty, one coat of primer, two coats of Asian premium emulsion.
MS grills shall be painted with one coat of zinc chromate primer and finished with two coats of synthetic enamel paint.
External walls shall have one coat of cement-based textured finish, one coat of exterior primer, and two coats of weather shield max.
SANITARY
Sanitary & CP Fittings:
All toilets shall have concealed wall hung closets with soft closing seat covers from JAQUAR/ROCA.
Health Faucet from JAQUAR/ROCA.
All toilets shall have a white wash basin with necessary fittings from JAQUAR/ROCA.
Overhead shower and Arm from JAQUAR/ROCA.
ELECTRICAL & POWER BACK UP
3 phase electricity supply and independent meters.
FRLS wires from HAVELLS.
Split AC points for Living, Dining & all bedrooms.
Modular switches and sockets of HAVELLS.
Earth leakage circuit breaker to prevent shock.
DG power back for the flats and common area excluding A/C.
TV, telephone points in all bedrooms.
2-way switches for all bedrooms.
PLUMBING
Inner Plumbing
Bathroom and kitchen water lines with CPVC pipes.
Overhead tanks to bathroom and kitchen water lines with UPVC pipes.
Outer Plumbing
Outer waste line, soil line, rainwater harvesting lines shall be with 4 inches and 6 inches diameter of 4 kg/SQ.CM pressure with necessary specials of PVC pipes.