STRUCTURE
Structural System: RCC Framed structure designed for seismic compliant (Zone – 3)
Masonry: 200mm for external walls & 100mm for internal walls
Floor- Floor height (incl. slab): Will be maintained at 3000mm
ATT: Anti–termite treatment will be done
WALL FINISH
Internal walls: Finished with 2 coats of putty, 1 coat of primer & 2 coats of Premium emulsion
Ceiling: Finished with 2 coats of putty, 1 coat of primer & 2 coats of Tractor emulsion
Exterior walls: Exterior faces of the building finished with 1 coat of primer & 2 coats of exterior Emulsion paint with color as per the architect’s design
Bathroom: Glazed/Matte ceramic Tile up to 2250mm height of size 300x450mm & above the false ceiling will be finished with a coat of primer
Kitchen: Ceramic wall tile of size 300x450mm for a height of 600mm above the countertop finished level
Toilet ceiling: Grid-type false ceiling
FLOOR FINISH WITH SKIRTING
Foyer, Living, Dining, Bedrooms & Kitchen: Vitrified tiles of size 600x600mm
Bathroom: Anti-skid ceramic tiles of size 300x300mm
Balcony: Anti-skid vitrified tiles of size 300x300mm
Private open terrace (if applicable): Pressed tiles finish
KITCHEN & DINING
Kitchen: The platform will be finished with a granite slab of 600mm wide at a height of 850mm from the finished floor level
Electrical point: For chimney & water purifier
CP fitting: Cera OR equivalent brand
Sink: Stainless Steel sink without drain board
BALCONY
Handrail: MS handrail as per architect’s design
ELECTRICAL POINTS
Power Supply : 3 PHASE power supply connection
Safety device: MCB & ELCB (Earth leakage Circuit breaker)
Switches & sockets: Modular box & modular switches & sockets of Schneider or equivalent will be provided
Wires: Fire Retardant Low Smoke (FRLS) copper wire of a quality IS brand Polycab or equivalent will be provided
TV: Point in Living & in any one of the Bedrooms and provision in other bedrooms
Telephone: Point in Living & in any one of the Bedrooms
Data: Point in Living & in any one of the Bedrooms
Split-air conditioner: Points will be given in the Living, Dining and all Bedrooms
Exhaust fan: Point will be given in all bathrooms
Geyser: Point will be given in all bathrooms
Back-up : 500W for 2BHK & 400W for 1BHK